50kW High-frequency Micro-control Radiography X-ray System YSX0308
1. Our modern high frequency x ray machine is
microcomputer procedure control and high frequency single x-ray
tube and diagnostic table x-ray equipment.
2. To be equipped with 150kV, 50kW X-ray tube. High-frequency
technology Constant DC output, not only improve the image quality
and greatly reduce the radiation hazards to patients.
3. Main circuit using intelligent modules, not only to improve the
radiation output reproducibility and linearity, while ensuring
long-term safety of the machine is running reliably and has fault
self-diagnosis function.
4. This high frequency x ray machine has 2000 kinds of
exposure conditions, also, exposure conditions can be chooses
according to user’s demand, which providing a great convenience for
clinical use.
5. The vertical and horizontal movement of radiography tabletop is
flexible and can bear for a variety of specifications of cassettes;
it is easy to use and beautiful in design.
6. It is applicable to the hospital for general photography,
photographic filter line browser, apparatus procedures radiography
(APR), etc.
| Department | Technology Parameters | ||||||
| High voltage generator control table and high voltage transform assemble | Power | Voltage | 380V±10% | ||||
| Capacity | 50Hz±1Hz | ||||||
| Frequency | ≥32KVA | ||||||
| Inner resistance | ≤0.3 | ||||||
| Tube voltage | 45-125kV step 1kV | ||||||
| Tube currency | 30-500mA 8 shift | ||||||
| Exposure time | 0.01-5.0S 25 shift | ||||||
| Max rated capacity | mA | 600 | 500 | 400 | 500 | 400 | |
| kV | 71 | 84 | 106 | 84 | 106 | ||
| X-ray assembly | Type of x-ray | XD52-30.50/125 | |||||
| Focus | 1×1.2×2 double focal | ||||||
| Rated rotate speed of anode | 2800r/min | ||||||
| Manually beam limited device | Model | Manually continuous adjusted field of | |||||
| Field view | View, luminosity≥100LX, 1minlimit-time device | ||||||
| CDG Multi function radiography table | Moving table | Lengthways | ±600mm | Electromagnetism locking | |||
| Across | ±120mm | ||||||
| Mobile beam filtration grid | Grid density | 28L/cm | |||||
| Grid ratio | 8:1 | ||||||
| Focusing distance | 100cm | ||||||
| Scope of moving | ≥600mm | ||||||
| Radiography item | 5×7, 8×10, 10×12, 11×14, 12×15", 14×14, 14×17 | ||||||
| Distance from surface to film | 75mm | ||||||
| Height of bed | 700mm | ||||||
| Moving pillar | ±180°, per 90°orientation, moving lengthways ≥1500mm | ||||||
| Bulb tube | Rotate the cross arm±180, ascend $ descend 1100mm | ||||||
| LSJ pillar radiography frame | The scope of ascend and descend | 1450mm | |
| The minimum distance from focal spot | 380mm | ||
| Radiography item | 8"×10"', 10"×12", 11"×14", 12"×15", 14"×14", 14"×17" | ||
| Fixed beam filtration role | Grid density | 40L/cm | |
| Grid radio | 10:1 | ||
| Focal distance | 180cm | ||
Do you want to show products of your own company? Join FREE now!