50kW High frequency RF control radiography X-ray machine
YSX0606
1. 50KW Microcomputer control x-ray radiography assemble.
2. Total 432 storage combination controlled by element such as kV
mA S is applied radiography for the following filed three body
position, fat middle and thin body type, automatic detect and
display cod of mistake in system, send warning signal, detect
accuracy and maintain.
3. X-ray tube capacity protection, anode starting-up protection and
radiograph time-limit protection device semi-conduct controlled,
fluoroscopy computed time device, x-ray tube over-hot protectorate
provided, ensure x-ray tube run safely long time, improve accuracy
of kV mA S.
4) Bulb type over remote-controlled diagnostic table and image
intensifier television system are installed. They realize not only
bright operation, but also supply convenience for science resonator
suffer are reduced. Specifications of automatic spot-film are
abundant. There are also automatic collimators for users
convenience.
5. Applied in all kinds of hospital for radiography such as general
body, beam filtration, and chest.
Department | Technology Parameters | |||
High voltage generator control table and high voltage transform assemble | Fluoroscopy | Tube currency | 0.2-12.5mA continuous currency | |
Tube voltage | 40-150KV continuous voltage | |||
Radiography | Tube currency | 10-630mA shift | ||
Tube voltage | 40-125KV continuous voltage | |||
Exposure time | 0.01-10s 23 shift | |||
Power | Voltage | 380V±10% | ||
Frequency | 50Hz±1Hz | |||
Capacity | ≥50KVA | |||
Inner resistance | ≤0.15 | |||
X-ray assembly | Focus | 0.6/1.2mm double focal | ||
Power | 50KW | |||
Changed beam limited device | Diagnosis table YS09D | Automatic, adjusted field of view | ||
CS15Electro-motion diagnostic table | The table body rotation | -15°~0°~+90° | ||
Focus to film distance | 1100~1500mm,adjustable manual | |||
360°foot board | ||||
The table to height | 870mm | |||
Stationary grid | Grid density | 40L/cm | ||
Grid ration | 10:01 | |||
Focusing distance | 120cm | |||
Spot film device | Scope of moving | Longitudinal moving: 900mm; | ||
Transverse moving120mm | ||||
Specification of scope film | Full :8"×10", 10"×12", 11"×14", 14"×14" | |||
Two: 8"×10", 10"×12" | ||||
Three: 11"×14", 14"×14" | ||||
Four: 11"×14", 14"×14" | ||||
Medical television system | configuration | 9x-ray image intensifier made by Toshiba, CCD camera, 14 high resolution monitor | ||
14monitor | resolution | Horizontal center≥1000 TV line | ||
Gray scale | ≥10 grades | |||
Video width | >12MHZ | |||
Mode of scan | 625 lines, 5 field, Interlaced scanning | |||
Geometry distortion | <2% | |||
SNR | ≥40db | |||
Power supply | 220V 50Hz AC | |||
9x-ray image intensifier made by Toshiba | resolution | ≥46LP/mm | ||
Conversion modulus | 34cd/m2/GY/s | |||
Contra | ||||