KB-500c-6 Diagnostic table and x-ray tube romote control assemble Product frame: Technology parameters(Optional spare part) Department 性能参数 Highvoltage generator included KB-500C control table and 6G high voltage transtorm assemble
Fluoroslopy Tube currency 0.3-0.5mA Tube voltage 50-110kv automatic bright control Radiography Exposure time 0.01-5S、25shift Optional way
540storage exposure conditon,free choosed Tube voltage 45-125kv Tube currency 30-500ma,total eight shift Tube voltage 45-125kv,1kv Power voltage 380V±10% Frequency 50HZ±1HZ Capcity ≥32KVA Inner resistance ≦0.3 Choose way
Optional 540storage exposure conditon SC3FX-ray assembly Type of x-ray XD52-30.50/125 Focal spot Double focal 1×1,2×2 Rated rotate speed of anode 2800r/min CS02Aautomatic beam limited device
Manual beam filtration device
Continous Manually adjusted field of view automatic beam filtration devic
1min limit-time device CS90 Up bulb tube remote diagnostictable
Ratation of table -900~00~90 0 Moving crossive table ±120mm High of table 860mm Opress Max oppresure 70N±10N Distanc from focal to film
1100~1500mm、continous manual adjust Radiography item 8″×10″ ■ ■ 10″×12″ ■ ■ ■ ■ 11″×14″ ■ ■ ■ 14″×14″ ■ ■ 17″×14″ ■ ■ ■ ■ Scope of moving Moving lengthways 780mm Spotfilm Fixed beam filtration grid
Grid density 40L/cm Grid ratio 10: 1 Focusing distance 120cm Radiography item
5″×7″,8″×10″,10″×12″,10″×12″11″×14″12″×15″14″×14″14″×17″ Moving pillar
±180,per 90orientation,moving lengthways≥1500mm Bulb tube
Rotate the cross arm±1800,ascend $descend1100mm CDG1 multi function radiography table
Moving table Movinglengthways±600mm
Electromagnetism lockingSend out by foot Moving crossive±120mm Distance from surface to film 75mm High of bed CDG:750mm,CDG1:700mm Mobile beam filtration grid Grid density 28L/cm Grid ratio 8: 1 Focusing distance 100cm Scope of moving ≥600mm Radiography item
5″×7″,8″×10″,10″×12″, 11″×14″12″×15″14″×14″14″×17″ Moving pillar
±180,per 90orientation,moving lengthways≥1500mm Bulb tube
Rotate the cross arm±1800,ascend $descend1100mm Clinical x-ray video system with image intensifier Department Item Technology parameters 14 inch high resolution uncolour monitor
resolution Horizontal ≥1000lines grey ≥10 Video frequency bandwidth >12MHZ Scan method 625line ,50field,scan every line Picture false ﹤2% Singal operate rate ≥40db Power supply 220v 50hz commutation 9inch x-ray image intensifier resolution ≥46LD/mm Transform 34cd/m2/Ugy/s Contrast 10%field:30:1¢10mm field:18:1 Ccd vidicon Item 1/2.anti-light,CCIR752×586 Features: 1、
Micro-computered control double diagnostic table and x-ray tube equipment with 500MA 2、
Total 540 storage radiography program,according to disagonic situation,rapidly choose radiography parameters,self-set parameters, easy to use 3、
X-ray capacity protection ,kv automatic compensation,Ma automatic steady can ensure the x-ray tube run safe longtime and improve the accuancy. 4、
Self-detect function,display mistake code and send singal easy to depend and maintain 5、
CS90 remote diagnostic table is computered control, automatic recongize item of box,track the field of view,finish all radiography item, big scope of totation of table and moving table, Achieve remote control, ruduce radiation to min. 6、
Equiped remote control diagnostic table tube assemble with image intensifier video system made by TOSHIBA, It make as possible as not only operate in bright room but also Advanc excellent image quality reduce radiation 7、
Applied in all kinds of hospital for radiography such as potfilm device、stomack、intestine、beam filtration 、body and chest . Standard equipped: Standard equipped
KB-500cComputered controled machine KB-500CControltable
6Ghigh transvoltagegenerator SC3F/SCIF-125x-ray assemble
YS127C/YS127High voltage cable
YS11S/CS02AManual and automaticBeam filtration device
x-ray image intensifiervideo system
CS15Up bulb tube remoteDiagonstictable CDGIMulti-functionRadiographytable
X-ray image intensifier video
|
|