VET Portable & high frequency veterinary x-ray unit:YSVET0112
Features:
1. Integrated with high frequency and high voltage generator, main
control system, intelligent computer system, numeric display and
beam limited device, it is designed and manufactured precisely and
compactly, more flexibly and widely used.
2. Using the technique of inverse converter for HF and
computer-controlled closed-loop adjusting System, stable high
voltage output is generated and high-quality images can be
obtained.
3. Using the buttons of KV and mAs to adjust the photographic
parameters, display them on high-brightness LEDs, interlock
protection conditions is determined by software, which is
convenient for doctors to operate.
4. X-ray Tube is placed in lead cylinder which can effectively
shield the gamma leakage and protect environment and operators’
safety.
5. 20 radiographic conditions are preset and can be customized
according to user requirements.
6. Photography Time is controlled precisely by computer, host will
automatically delay 10 seconds at the end of photography which can
effectively control photography interval, avoid overloading and
achieve automatic protection.
7. Hand-controlled and remote-controlled photography function
8. Using computer to monitor fault sources, the computer will cut
all outputs, display fault code and identify the fault reasons if a
fault appears.
9. Suitable for all kinds of cassettes.
Structural performance:
1. Radiography can be launched after X-ray apparatus is suspended
on the frame.
2. The fuselage of X-ray apparatus is suspended on the frame, can
rotate left and right at larger than or equal to ±90°, X-ray tube
head can rotate at 90°which is easy to project in different angles.
3. The arm can move up and down, has Servo-balance and lock-up
device.
4. The fuselage of X-ray apparatus weighs 19kg, is more convenient
to carry.
The frame weighs 23 kg, is more flexible to move at different
places.
5. The frame can be disassembled and folded quickly, then putted
into trunk,
which can make out-call more convenient.
Instruments container is an additional option.
Usage: outgoing save, orthopaedics hospital, basic level physical,
hairdressing and reshaping, ICU ward, emergency call, community
medical treatment, rural area medical treatment, general medical
treatment.
Main specifications and parameters: | Max. photograph tube voltage | 90kV/22mA |
| Max. photograph tube current | 50mA |
| Max. Output | 2.0kW |
| Exposal time | 0.01s~4.0s |
| MAS scope | 0.5mAs~160mAs with 46 alternations |
| Voltage scope | 40~90kV KV with 26 alternations |
| Main frequency | 30kHz |
| Max. light field | ≤35CMX35CM @65CM SID |
| Focus size | 2.3mm |
| Resistance |